Honeywell Thermostat RTH7400RTH7500 User Manual - Honeywell Thermostat Manual Download

Latest

Sunday, April 5, 2020

Honeywell Thermostat RTH7400RTH7500 User Manual

Operating Manual RTH7400/RTH7500 Series Programmable Thermostat 69-2222ES-07 This manual covers the RTH7400 and RTH7500 models. (Pull thermostat from wallplate and turn over to find model number) This thermostat contains a Lithium battery which may contain Perchlorate material. Perchlorate Material—special handling may apply, See www.dtsc.ca.gov/hazardouswaste/perchlorate CAUTION: EQUIPMENT DAMAGE HAZARD. To prevent possible compressor damage, do not operate cooling system when outdoor temperature is below 50°F (10°C). Need Help? For assistance with this product please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502 Read and save these instructions. ® U.S. Registered Trademark. Patents pending. US Patent No. 6,595,430; 7,114,554; 7,274,972; 7,225,054 and other patents pending Copyright © 2013 Honeywell International Inc. All rights reserved. RTH7400/RTH7500 Series Table of contents About your new thermostat Appendices Thermostat features.....................................2 Battery replacement...................................19 Programming at a glance.............................3 Customer assistance.................................20 Quick reference to controls..........................4 In case of difficulty.....................................21 Quick reference to status display.................5 Limited warranty.........................................23 Programming & Operation Clock setting................................................6 Fan setting...................................................7 This thermostat is ready to go! System setting.............................................8 Your new thermostat is pre-programmed Using program schedules............................9 and ready to go. Program schedule overrides......................13 See page 3 to check settings. Auto Changeover.......................................15 Filter reminder............................................17 Special features.........................................18 1 69-2222ES—07 Operating Manual About your new thermostat Congratulations! You’ve just purchased the world’s most advanced, easy-to-use thermo- stat. It has been designed to give you many years of reliable service and climate control. Features • Easy-to-follow menu programming. • One-touch temp control overrides program schedule at any time. • Precise comfort control keeps temperature within 1°F of the level you set. • Change/check reminder lets you know when to replace furnace filter. • Large display with backlight is easy to read—even in the dark. 69-2222ES—07 2 RTH7400/RTH7500 Series This thermostat is ready to go! Your new thermostat is pre-programmed and ready to go. All you have to do is set the time and day. Then check the settings below and change if needed: 1. Set clock.................................................................................................See page 6 2. Select fan setting: Preset to Auto........................................To change, see page 7 3. Select system setting: Preset to Heat.................................To change, see page 8 4. Program schedules: Preset to energy-saving levels while you’re at work or asleep (assumes you wake at 6 am, leave at 8 am, return at 6 pm and go to bed at 10 pm)......................................................................To change, see pages 10–14 ONE-TOUCH TEMP CONTROL: You can override the program schedule at any time, and manually adjust the temperature (see pages 13–14). 3 69-2222ES—07 Operating Manual Quick reference to controls Arrow buttons Press to adjust temperature (see pages 11-14), or to make selections from screen menus. System & Fan Press to select fan operation (see page Clock & More 7) or system (see Press to set clock (see page 8). page 6) or furnace filter reminder. M28426A Schedule Press to set program schedule (see pages 11-12). 69-2222ES—07 4 RTH7400/RTH7500 Series Quick reference to status display Current day of week Current inside temperature Current time Mon Temperature setting Smart Response® Set to Technology in effect (see page 15) 75 : AM 75 Recovery 6 01 Heat On System Fan Auto Cool System & Fan Schedule Clock & Mode System setting M28078 (see page 8) Fan setting Other display messages: (see page 7) • Cool On: Cooling system is activated • Heat On: Heating system is activated • Aux Heat On: Auxiliary heating system is activated (heat pump systems only) 5 69-2222ES—07 Operating Manual Clock setting Press CLOCK To set the current time display, press CLOCK, then press s or t to adjust the time. Press s t System & Fan Schedule Clock & More and hold or to advance the time more quickly. Press DONE to save & exit (or press GO BACK M28079 Adjust time, then press DONE to exit without changing the time). Mon Note: The real-time clock should never require adjustment since it automatically updates for daylight savings time, and stores 6:01AM all date/time information. Note: To change the current week day display, see System Setup in your Go Back Done Installation Guide. M28080 69-2222ES—07 6 RTH7400/RTH7500 Series Fan setting Press SYSTEM & FAN Press SYSTEM & FAN, then FAN to select fan operation: System & Fan Schedule Clock & More • On: Fan is always on. • Auto: Fan runs only when the heating or cooling system is on. M28081 Press FAN to select mode, then press DONE System Fan Auto Heat System Fan Done M28082 7 69-2222ES—07 Operating Manual System setting Press SYSTEM & FAN Follow steps at left to select system: • Heat: Thermostat controls only the heating System & Fan Schedule Clock & More system. • Cool: Thermostat controls only the cooling system. M28081 Press SYSTEM to select mode, • Auto: Thermostat automatically selects heating then press DONE or cooling depending on the indoor temperature. • Off: All systems are off. • Em Heat (only for heat pumps with auxiliary heat): Thermostat controls Emergency and Auxiliary Heat. Compressor is locked out. System Fan Auto Heat Note: The Auto and Em Heat system settings may not appear, depending on how your thermostat System Fan Done was installed. M28083 69-2222ES—07 8 RTH7400/RTH7500 Series Save money by setting program schedules It’s easy to program your system for maximum energy savings. You can program four time periods each day, with different settings for weekdays and weekends. WAKE Set to the time you awaken and the temperature you want 6:00 am during the morning, until you leave for the day. 70 ° LEAVE Set to the time you leave home and the temperature you 8:00 am want while you are away (usually an energy-saving level). 62 ° RETURN Set to the time you return home and the temperature you 6:00 pm want during the evening, until bedtime. 70 ° SLEEP Set to the time you go to bed and the temperature you want 10:00 pm overnight (usually an energy-saving level). ° 62 9 69-2222ES—07 Operating Manual Energy saving settings for maximum cost savings This thermostat is pre-set with energy saving program settings. We recommend these settings, since they can reduce your heating/cooling expenses. (See next page to adjust times and temperatures of each time period.) Heat (Mon-Fri) Cool (Mon-Fri) Heat (Sat-Sun) Cool (Sat-Sun) Wake ° ° ° ° (6:00 am) 70 78 70 78 Leave ° ° ° ° (8:00 am) 62 85 62 85 Return ° ° ° ° (6:00 pm) 70 78 70 78 Sleep ° ° ° ° (10:00 pm) 62 82 62 82 69-2222ES—07 10 RTH7400/RTH7500 Series To adjust program schedules (RTH7400 only) Press SCHEDULE 1. Press SCHEDULE, then EDIT to see weekdays. System & Fan Schedule Clock & More 2. Press SELECT DAY to highlight Mon-Fri (they will share the same settings). 3. Press NEXT STEP twice, then press s or t to set Press EDIT M28084 Wake time for selected days. 4. Press NEXT STEP, then s or t to set Heat Go Back Edit View temperature for this time period. 5. Press NEXT STEP, then s or t to set Cool M28085 temperature for this time period. MON Set to 6. Repeat steps 3-5 to program other time periods Period TUE Wake (LEAVE, RETURN, SLEEP), then press DONE. WED 6:00 AM 62 7. Repeat steps 1-6 to program Saturday/Sunday. THU Heat (Press s or t until the desired day is flashing, then FRI press SELECT DAY.) 8. Press DONE to save & exit. Go Back Next Step Done M28086 Select day(s) Select time Select temp 11 69-2222ES—07 Operating Manual To adjust program schedules (RTH7500 only) Press SCHEDULE 1. Press SCHEDULE, then EDIT to see weekdays. 2. Press SELECT DAY. You can select multiple days to System & Fan Schedule Clock & More program with the same settings. 3. Press NEXT STEP twice, then press s or t to set Wake time for selected day(s). Press EDIT M28084 4. Press NEXT STEP, then s or t to set Heat Go Back Edit View temperature for this time period. 5. Press NEXT STEP, then s or t to set Cool temperature for this time period. M28085 6. Repeat steps 3-5 to program other time periods MON Set to Period TUE (LEAVE, RETURN, SLEEP), then press DONE. Wake WED : AM 62 7. Repeat steps 1-6 to program any remaining days. THU 6 00 Heat (Press s or t until the desired day is flashing, FRI then press SELECT DAY.) 8. Press DONE to save & exit. Go Back Next Step Done M28086 Select day(s) Select time Select temp 69-2222ES—07 12 RTH7400/RTH7500 Series Program schedule override (temporary) Adjust temperature Press s or t to immediately adjust the temperature. This will temporarily override the Mon temperature setting for the current time period. Temporary Set to The new temperature will be maintained until the next time period. 62 : AM 68 6 08 Heat On When the timer expires, the program schedule System Fan Auto will resume and set the temperature to the level Heat you’ve programmed for the current time period. Use To cancel the temporary setting at any time, System & Fan Schedule Clock & More press USE SCHEDULE. M28087 Press USE SCHEDULE to resume program schedule 13 69-2222ES—07 Operating Manual Program schedule override (permanent) Adjust temperature Press s or t to adjust temperature, then press HOLD. This will turn off the program schedule. Mon Whatever temperature you set will be Set to maintained 24 hours a day, until you manually change it, or press USE SCHEDULE to cancel 62 6:08 AM 68 “Hold” and resume the program schedule. System Fan Auto Heat Permanent Hold Hold Cancel M28088 Press HOLD to turn off program schedule and maintain set temperature 69-2222ES—07 14 RTH7400/RTH7500 Series AboutAuto Changeover your new thermostat Use this feature in climates where both air conditioning and heating are used on the same day. When the system mode is in Auto, the thermostat automatically selects heating or cooling depending on the indoor temperature. While in the Auto mode, if a schedule override takes place (temporarily or permanently) the thermostat will automatically adjust the cooling and heating settings to maintain a 3-degree separation between the cool and heat settings. For example, if the heat temperature is raised to where it gets within 3-dgrees of the cool setting, the display will show an up arrow next to “cool” to show the thermostat is raising the cool setting up to maintain a 3-dgreee separation. The display will also show both “Auto” and either “Heat” or “Cool” for which temperature setting you are currently adjusting. Press the system button to select between the heat and cool to view/adjust either mode. 15 69-2222ES—07 Operating Manual AboutAuto Changeover your new thermostat If the cool temperature is lowered to where it gets close to the heat setting, an arrow next to heat will show the thermostat is lowering the heat setting down to maintain a 3-degree separation. Tue Temporary 74Set To : PM 69 1 09 Heat System Auto Fan Auto Cool Heat The triangle indicates the cool temperature is System increasing to maintain 3 degrees between heat and cool settings. Hold Cancel M27486 CAUTION: To avoid possible compressor damage, do not use Auto Changeover if the outside temperature drops below 50°F (10°C). 69-2222ES—07 16 RTH7400/RTH7500 Series AboutFilter reminder your new thermostat Press RESET after changing filter If activated during installation, the furnace filter Change Filter Set to reminder alerts you when it is time to replace your filter. 70 : AM 70 Press RESET after changing the filter, to restart 6 01 Heat On the timer. System Fan Auto Heat To reset the reminder interval before it expires: 1. Press MORE, then NEXT. Reset Schedule Clock & More 2. Press RESET. 3. Press DONE to save and exit. M28089 Press MORE to reset reminder interval 60 Days Reset Next Done M28090 17 69-2222ES—07 Operating Manual Special features Smart Response® Technology: This feature allows the thermostat to “learn” how long the furnace and air conditioner take to reach programmed temperature settings, so the temperature is reached at the time you set. For example: Set the Wake time to 6 am, and the temperature to 70°. The heat will come on before 6 am, so the temperature is 70° by the time you wake at 6. The message “Recovery” is displayed when the system is activated before a scheduled time period. Compressor Protection: This feature forces the compressor to wait a few minutes before restarting, to prevent equipment damage. During the wait time, the message “Wait” is displayed on screen. Auto Changeover: This feature is used in climates where both air conditioning and heating are used on the same day. When the system is set to Auto, the thermostat automatically selects heating or cooling depending on the indoor temperature. Heat and cool settings must be at least 3 degrees apart. The thermostat will automatically adjust settings to maintain this 3-degree separation. CAUTION: To avoid possible compressor damage, do not use Auto Changeover if the outside temperature drops below 50°F (10°C). 69-2222ES—07 18 RTH7400/RTH7500 Series Battery replacement Grasp thermostat and pull to Batteries are optional (to provide backup power) if remove from wallplate your thermostat was wired to run on AC power when installed. Install fresh batteries immediately when the LO BATT warning begins flashing. The warning flashes about 30 days before batteries are depleted. Even if the warning does not appear, you should replace batteries once a year, or before leaving home for more than a month. M28103 Insert 2 fresh AA alkaline batteries M28101 19 69-2222ES—07 Operating Manual Customer assistance For assistance with this product, please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502. 69-2222ES—07 20 RTH7400/RTH7500 Series AboutIn case your of difficulty new thermostat If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily. Display is blank • Check circuit breaker and reset if necessary. • Make sure power switch at heating & cooling system is on. • Make sure furnace door is closed securely. • If thermostat is battery powered, make sure fresh AA alkaline batteries are correctly installed (see page 19). No response to Make sure heating and cooling temperatures are set to acceptable ranges: key presses (or • Heat: 40° to 90°F (4.5° to 32°C). temperature will • Cool: 50° to 99°F (10° to 37°C). not change) 21 69-2222ES—07 Operating Manual AboutIn case your of difficulty new thermostat Heating or cooling • Press SYSTEM to set system to Heat. Make sure the temperature is set system does not higher than the Inside temperature. respond • Press SYSTEM to set system to Cool. Make sure the temperature is set lower than the Inside temperature. • Check circuit breaker and reset if necessary. • Make sure power switch at heating & cooling system is on. • Make sure furnace door is closed securely. • If “Wait” is displayed, the compressor protection timer is on. Wait 5 minutes for the system to restart safely, without damaging the compressor (see page 18). 69-2222ES—07 22 RTH7400/RTH7500 Series About1-year yourlimited new warranty thermostat Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell’s option). If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to the place from which you pur- chased it; or (ii) call Honeywell Customer Care at 1-800-468-1502. Customer Care will make the determination whether the product should be returned to the following address: Honeywell Return Goods, Dock 4 MN10-3860, 1985 Douglas Dr. N., Golden Valley, MN 55422, or whether a replacement product can be sent to you. This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer. 23 69-2222ES—07 Operating Manual 1-year limited warranty Honeywell’s sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequen- tial damages, so this limitation may not apply to you. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE-YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Honeywell Customer Relations, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502. 69-2222ES—07 24 RTH7400/RTH7500 Series 25 69-2222ES—07 Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 http://yourhome.honeywell.com ® U.S. Registered Trademark. © 2013 Honeywell International Inc. 69-2222ES—07 M.S. Rev. 11-2013 Printed in U.S.A. Manual de uso Serie RTH7400/RTH7500 Termostato programable 69-2222ES-07 Este manual incluye el modelos RTH7400 y RTH7500. (Retire el termostato de la placa de montaje y gírelo para ver el número de modelo.) Este termostato tiene una batería de litio que puede contener perclorato. Perclorato: puede ser necesario manipularlo con métodos especiales. Visite www.dtsc.ca.gov/hazardouswaste/perchlorate PRECAUCIÓN: PELIGRO DE DAÑO DEL EQUIPO. Para impedir un posible daño al compresor, no haga funcionar el sistema de refrigeración cuando la temperatura exterior sea inferior a 50° F (10° C). ¿Necesita ayuda? Para recibir asistencia con este producto visite http://yourhome.honeywell.com o llame gratis al Servicio de Atención al Cliente Honeywell al 1-800-468-1502 Lea y conserve estas instrucciones. ® Marca registrada en EE.UU. Patentes pendientes. Patente en EE.UU: Nº 6,595,430; 7,114,554; 7,274,972; 7,225,054 y otras patentes pendientes Copyright © 2013 Honeywell International Inc. Todos los derechos reservados. Serie RTH7400/RTH7500 Índice de contenidos Acerca de su nuevo termostato Apéndices Funciones del termostato............................2 Instalación de las baterías.........................19 Programación a simple vista........................3 Asistencia al cliente...................................20 Referencia rápida de los controles..............4 En caso de dificultades..............................21 Referencia rápida de la pantalla..................5 Garantía limitada........................................23 Programación y operación Ajuste del reloj.............................................6 Ajuste del ventilador.....................................7 ¡Este termostato Ajuste del sistema........................................8 está listo para usar! Uso de horarios de programas....................9 El nuevo termostato viene preprogramado Anulaciones de horarios de programas.....13 y listo para usar. Ver página 3 Conversión automática..............................15 para verificar los ajustes. Recordatorio de cambio de filtro................17 Funciones especiales................................18 1 69-2222ES—07 Manual de uso Acerca de su nuevo termostato ¡Felicitaciones! Usted acaba de comprar el termostato más avanzado y más fácil de usar en todo el mundo. Ha sido diseñado para proporcionarle muchos años de servicio confiable y control del clima. Funciones • Programación con menú fácil de seguir. • El control de temp. de un sólo toque anula el horario programado en cualquier momento. • Preciso control de comodidad que mantiene la temperatura dentro del rango de 1º F del nivel que usted fije. • Recordatorios para cambiar/controlar le avisan cuándo substituir el filtro de la estufa. • Pantalla grande con luz de fondo fácil de leer—incluso en la oscuridad. 69-2222ES—07 2 Serie RTH7400/RTH7500 Este termostato está listo para usar! El nuevo termostato viene preprogramado y listo para usar. Todo lo que tiene que hacer es ajustar la hora y el día. Luego verifique los siguientes ajustes y cámbielos si es nece- sario: 1. Ajuste la hora....................................................................................... Ver página 6 2. Seleccione el ajuste del ventilador: Predeterminado en Auto............... Ver página 7 3. Seleccione el ajuste del sistema: Predeterminado en Heat.................. Ver página 8 4. Horarios de programas: Predeterminado en niveles de ahorro de energía mientras trabaja o duerme (supone que se despierta a las 6 AM, sale a las 8 AM, vuelve a las 6 PM y se acuesta a las 10 PM).............................. Ver páginas 10-14 CONTROL DE TEMP. DE UN SÓLO TOQUE: En cualquier momento, puede anular el horario de programas y ajustar a mano la temperatura (ver páginas 13-14). 3 69-2222ES—07 Manual de uso Referencia rápida de los controles Oprima para ajustar la temperatura (ver páginas 11-14), o para hacer selecciones de menús. System & Fan Oprima para seleccionar el Clock & More funcionamiento del Oprima para ajustar ventilador (ver página el reloj (ver página 7) o sistema (ver 6) o recordatorio de página 8). cambio de filtro de la estufa. M28426A Schedule Oprima para anular el horario de programa (ver páginas 11-12). 69-2222ES—07 4 Serie RTH7400/RTH7500 Referencia rápida de la pantalla Día de la semana actual Temperatura interior actual Hora actual Mon Ajuste de temperatura Smart Response® Set to Technology activado (ver página 15) 75 : AM 75 Recovery 6 01 Heat On System Fan Auto Cool Ajustes del sistema System & Fan Schedule Clock & Mode (ver página 8) M28078 Ajustes del ventilador Otros mensajes de pantalla: (ver página 7) • Cool On : El sistema de refrigeración está activado • Heat On : El sistema de calefacción está activado • Aux Heat On : El sistema de calefacción auxiliar está activado (bombas de calefacción solamente) 5 69-2222ES—07 Manual de uso Ajuste del reloj Oprima CLOCK Para ajustar la hora actual en pantalla, oprima CLOCK, luego oprima s o t para ajustar la System & Fan Schedule Clock & More hora. Mantenga oprimido s o t para avanzar la hora con más rapidez. Oprima DONE para guardar y salir (u oprima M28079 Ajuste la hora, luego oprima DONE GO BACK para salir sin cambiar la hora). Mon Nota: El reloj de hora-real no debería requerir ajuste nunca ya que se actualiza automáticamente de acuerdo al horario de 6:01AM ahorro de energía diurno, y guarda toda la información de fecha/hora. Nota: Para cambiar el día actual de la semana Go Back Done en pantalla, consulte Configuración del Instalador en su Guía de Instalación. M28080 69-2222ES—07 6 Serie RTH7400/RTH7500 Ajustes del ventilador Oprima SYSTEM & FAN Oprima SYSTEM & FAN, entonces FAN para seleccionar el funcionamiento del ventilador: System & Fan Schedule Clock & More • On: El ventilador está siempre encendido. • Auto: El ventilador funciona sólo cuando el sistema de calefacción o de refrigeración M28081 está encendido. Oprima FAN al modo selecto, luego oprima DONE System Fan Auto Heat System Fan Done M28082 7 69-2222ES—07 Manual de uso Ajustes del sistema Oprima SYSTEM & FAN Siga los pasos en la izquierda para seleccionar: • Heat: El termostato controla sólo el sistema de System & Fan Schedule Clock & More calefacción. • Cool: El termostato controla sólo el sistema de refrigeración. M28081 • Auto: El termostato selecciona Oprima SYSTEM al modo selecto, automáticamente la calefacción o refrigeración luego oprima DONE de acuerdo a la temperatura interior. • Off: Los sistemas de calefacción y refrigeración están apagados. • Em Heat: (Sólo para bombas de calefacción con calefacción auxiliar). El termostato controla System Fan Auto la calefacción de emergencia y la auxiliar. El Heat compresor está bloqueado. System Fan Done Nota: Las Auto y Em Heat opciones pueden no aparecer, dependiendo de cómo su termóstato fue instalado. M28083 69-2222ES—07 8 Serie RTH7400/RTH7500 Ahorre dinero con el ajuste de los horarios de programas Es fácil programar su sistema que permite un ahorro máximo de energía. Usted puede programar cuatro períodos de tiempo por día, con diferentes configuraciones para los días de semana y los fines de semana. “WAKE” Programe la hora en que se despierta y la temperatura que quiere 6:00 am durante la mañana, hasta que usted se va de su casa. 70 ° “LEAVE” Programe la hora en que usted se va de su casa y la temperatura que 8:00 am quiere mientras no esté en su casa (por lo general, un nivel de ahorro 62 ° de energía). “RETURN” Programe la hora en que regresa a su casa y la temperatura que quiere 6:00 pm durante la tarde hasta que se va a dormir. 70 ° “SLEEP” Programe la hora en que usted se va a dormir y la temperatura que 10:00 pm quiere durante toda la noche (por lo general, un nivel de ahorro de ° energía). 62 9 69-2222ES—07 Manual de uso Configuraciones de ahorro de energía para mayores ahorros de gastos Este termostato viene predeterminado con configuraciones de programa para ahorro de energía. Recomendamos estos ajustes, dado que pueden reducir sus gastos de calefacción/refrigeración. (Ver la página siguiente para ajustar las horas y temperaturas para cada período). “Heat” “Cool” “Heat” “Cool” (Lun-Vier) (Lun-Vier) (Sab-Dom) (Sab-Dom) “Wake” ° ° ° ° (6:00 am) 70 78 70 78 “Leave” ° ° ° ° (8:00 am) 62 85 62 85 “Return” ° ° ° ° (6:00 pm) 70 78 70 78 “Sleep” ° ° ° ° (10:00 pm) 62 82 62 82 69-2222ES—07 10 Serie RTH7400/RTH7500 Para ajustar los horarios de programas (RTH7400 solamente) Oprima SCHEDULE 1. Oprima SCHEDULE, luego oprima EDIT. System & Fan Schedule Clock & More 2. Oprima SELECT DAY para seleccionar Lun-Vier (compartirán los mismos ajustes). 3. Oprima NEXT STEP dos veces, luego oprima s o t Oprima EDIT M28084 para fijar la hora Wake. s t Go Back Edit View 4. Oprima NEXT STEP, luego oprima o para fijar la temperatura Heat para este período. 5. Oprima NEXT STEP, luego oprima s o t para fijar M28085 la temperatura Cool para este período. MON Set to Period 6. Repita los pasos 3-5 para programar otros períodos TUE Wake (LEAVE, RETURN, SLEEP), luego oprima DONE. WED : AM 62 THU 6 00 Heat 7. Repita los pasos 1-6 para programar Sab-Dom. FRI (Oprima s o t hasta que está destellando el día deseado, después oprima SELECT DAY.) Go Back Next Step Done 8. Oprima DONE para guardar y salir. M28086 Día o días El tiempo La temperatura 11 69-2222ES—07 Manual de uso ÀPara propos ajustar du los thermostat horarios de programas (RTH7500 solamente) Oprima SCHEDULE 1. Oprima SCHEDULE, luego oprima EDIT. 2. Oprima SELECT DAY. Usted puede programar días System & Fan Schedule Clock & More múltiples con los mismos ajustes. 3. Oprima NEXT STEP dos veces, luego oprima s o t Oprima EDIT M28084 para fijar la hora Wake. 4. Oprima NEXT STEP, luego oprima s o t para fijar Go Back Edit View la temperatura Heat para este período. 5. Oprima NEXT STEP, luego oprima s o t para fijar la temperatura Cool para este período. M28085 MON Set to 6. Repita los pasos 3-5 para programar otros períodos Period TUE Wake (LEAVE, RETURN, SLEEP), luego oprima DONE. WED 6:00 AM 62 7. Repita los pasos 1 al 6 para programar THU Heat cualesquiera días restantes. (Oprima s o t hasta FRI que está destellando el día deseado, después oprima SELECT DAY.) Go Back Next Step Done 8. Oprima DONE para guardar y salir. M28086 Día o días El tiempo La temperatura 69-2222ES—07 12 Serie RTH7400/RTH7500 ÀAnulación propos du (temporaria) thermostat de horario de programas Ajuste la temperatura Oprima s o t para ajustar inmediatamente la temperatura. Esto anulará temporariamente el Mon ajuste de temperatura para el período actual. Temporary Set to La nueva temperatura se mantendrá hasta la hora que haya fijado. Cuando se cumpla 62 6:08 AM 68 el plazo, el horario de programa reanudará Heat On y ajustará la temperatura al nivel que haya System Fan Auto programado para el período actual. Heat Use Para cancelar los ajustes temporarios en System & Fan Schedule Clock & More cualquier momento, oprima USE SCHEDULE. M28087 Oprima USE SCHEDULE para reasumir horario del programa 13 69-2222ES—07 Manual de uso ÀAnulación propos du (permanente) thermostat de horario de programas Ajuste la temperatura Oprima s o t para ajustar temperatura, luego oprima HOLD. Esto apagará el horario de Mon programas. Set to Cualquier temperatura que fije se mantendrá 24 horas al día, hasta que la cambie manualmente, 62 6:08 AM 68 u oprima USE SCHEDULE para cancelar “Hold” y reanude el horario de programas. System Fan Auto Heat Permanent Hold Hold Cancel M28088 Oprima HOLD para cancelar horario del programa y para mantener temperatura determinada 69-2222ES—07 14 Serie RTH7400/RTH7500 ÀConversión propos du automática thermostat Utilice esta característica en climas donde se utilicen tanto el aire acondicionado como la calefacción durante el mismo día. Cuando el sistema está configurado en Auto (automático), el termostato elige automáticamente cuándo calentar o enfriar, dependiendo de la temperatura interior. Mientras está en la modalidad Auto (automático), si ocurre una anulación del cronograma (temporal o permanente) el termostato ajustará automáticamente las configuraciones de frío y calor para mantener una separación de 3 grados entre ellas. Por ejemplo, si la temperatura de calefacción se eleva a un punto donde queda a 3 grados de la configuración de aire acondicionado, la pantalla mostrará una flecha ascendente al lado de “cool” (frío) para mostrar que el termostato está elevando la configuración de frío para mantener una separación de 3 grados. La pantalla también mostrará tanto “Auto” (automático) como “Heat” (calor) o “Cool” (frío) para la configuración de temperatura que está actualmente ajustando. Presione el botón del sistema para elegir entre calor y el frío para ver/ajustar cualquier modalidad. 15 69-2222ES—07 Manual de uso ÀConversión propos du automática thermostat Si la temperatura fría desciende a donde queda cercana a la configuración de calefacción, una flecha al lado del calor mostrará que el termostato está bajando la configuración de calor para mantener una separación de 3 grados. Tue Temporary 74Set To : PM 69 1 09 Heat System Auto Fan Auto Cool Heat El triángulo indica que la temperatura fría está System aumentando para mantener 3 grados entre las configuraciones para calor y frío. Hold Cancel M27486 PRECAUCIÓN: Para evitar posibles daños al compresor, no utilice la Conversión Automática si la temperatura externa es inferior a 50ºF (10ºC). 69-2222ES—07 16 Serie RTH7400/RTH7500 ÀRecordatorio propos du thermostatde cambio de filtro Oprima RESET después de cambiar el filtro Si está activado durante la instalación, el Change Filter recordatorio del filtro de la estufa le alerta Set to cuando es hora de substituir su filtro. 70 : AM 70 Oprima RESET después de cambiar el filtro, para 6 01 Heat On recomenzar el contador de tiempo. System Fan Auto Heat Para cambiar el intervalo del recordatorio: 1. Oprima MORE, y después NEXT. Reset Schedule Clock & More 2. Oprima RESET. 3. Oprima DONE para guardar y salir. M28089 Oprima MORE para cambiar intervalo del recordatorio 60 Days Reset Next Done M28090 17 69-2222ES—07 Manual de uso ÀFunciones propos du especiales thermostat Smart Response® Technology: Permite que el termostato “aprenda” cuánto tiempo les lleva a la estufa y al acondicionador de aire alcanzar la temperatura programada, de modo que se alcance la temperatura a la hora fijada. Por ejemplo, fije la hora de levantarse a las 6 AM y la temperatura a 70°. La calefacción se encenderá antes de las 6 AM, para que la temperatura alcance los 70º cuando usted se despierte a las 6. El mensaje “Recovery” aparecerá en pantalla cuando el sistema se active antes del horario del período fijado. Protección del compresor: Esta función fuerza al compresor a esperar unos minutos antes de volver a encenderse, para prevenir daños. Durante el tiempo de espera, el mensaje “Wait” titila en la pantalla. Cambio automático: Cuando el sistema se fija en Auto, el termostato selecciona automáticamente calefacción o refrigeración de acuerdo a la temperatura del interior. PRECAUCIÓN: Para evitar daño posible del compresor, no utilice el cambio automático si la temperatura exterior cae debajo de 50° F (10° C). 69-2222ES—07 18 Serie RTH7400/RTH7500 ÀReemplazo propos du de thermostat baterías Sujete el termostato y hale para Las baterías son opcionales (para brindar alimentación separarlo de la placa de montaje de respaldo) si el cableado de su termostato se instaló para funcionar con CA. Instale baterías nuevas inmediatamente cuando comience a titilar el aviso LO BATT. El aviso titila alrededor de 30 días antes de que las baterías estén agotadas. Aunque el aviso no aparezca, debe reemplazar las baterías una vez al año, o antes de dejar su hogar por M28103 más de un mes. Inserte 2 baterías alcalinas AA nuevas M28101 19 69-2222ES—07 Manual de uso Asistencia al cliente Si necesita asistencia, visite http://yourhome.honeywell.com o llame al número gratuito de atención al cliente de Honeywell al 1-800-468-1502. 69-2222ES—07 20 Serie RTH7400/RTH7500 ÀEn propos caso de du dificultades thermostat Si usted tiene dificultades con su termostato, pruebe las sugerencias que figuran a con- tinuación. La mayoría de los problemas se pueden solucionar rápida y fácilmente. Pantalla en • Verifique el disyuntor y reinicie si es necesario. blanco • Asegúrese de que esté encendido el interruptor del sistema de calefacción y refrigeración. • Asegúrese de que esté bien cerrada la puerta de la estufa. • Si el termostato se alimenta a batería, asegúrese de que estén correctamente instaladas baterías alcalinas AA nuevas (ver página 19). Los ajustes de Asegúrese de que las temperaturas de calefacción y refrigeración se fijen en temperatura no los rangos adecuados: cambian • Heat: 40° a 90° F (4.5° a 32° C). • Cool: 50° a 99° F (10° a 37° C). 21 69-2222ES—07 Manual de uso ÀEn propos caso de du dificultades thermostat No responde • Oprima SYSTEM para fijar en sistema en Heat. Asegúrese de que la el sistema de temperatura de ajuste sea mayor que la temperatura interior. calefacción o de • Oprima SYSTEM para fijar en sistema en Cool. Asegúrese de que la refrigeración temperatura de ajuste sea menor que la temperatura interior. • Verifique el disyuntor y reinicie si es necesario. • Asegúrese de que esté encendido el interruptor del sistema de calefacción y refrigeración. • Asegúrese de que esté bien cerrada la puerta de la estufa. • Si “Wait” aparece en pantalla, el temporizador de protección del compresor está funcionando. Aguarde 5 minutos a que el sistema se reinicie de modo seguro, sin dañar el compresor (ver página 18). 69-2222ES—07 22 Serie RTH7400/RTH7500 ÀGarantía propos limitada du thermostat de 1 año Honeywell garantiza este producto, a excepción de la batería, por el término de un (1) año contra cualquier defecto de fabricación o de los materiales, a partir de la fecha de compra por parte del consumidor. Si en cualquier momento durante el período de garantía se verifica que el producto tiene un defecto o que funciona mal, Honeywell lo reparará o reemplazará (a elección de Honeywell). Si el producto tiene defectos, (i) devuélvalo, con la factura de venta u otra prueba de compra fechada, al lugar donde lo compró; o (ii) comuníquese con el Centro de atención al cliente de Honeywell al 1-800-468-1502. Atención al cliente decidirá si se debe devolver el producto a la siguiente dirección: Devolución de mercaderías de Honeywell, Dock 4 MN10-3860, 1985 Douglas Dr. N., Golden Valley, MN 55422, o si se le puede enviar un producto en reemplazo. Esta garantía no cubre los costos de extracción o reinstalación. Esta garantía no se aplicará si Honeywell demuestra que el defecto o mal funcionamiento estaba causado por daños ocurridos mientras el producto estaba en posesión de un consumidor. La única responsabilidad de Honeywell será reparar o reemplazar el producto dentro de los plazos establecidos anteriormente. HONEYWELL NO RESPONDERÁ POR LA PÉRDIDA O DAÑO DE NINGÚN TIPO, INCLUIDO EL DAÑO INCIDENTAL O INDIRECTO DERIVADO, DIRECTA O 23 69-2222ES—07 Manual de uso ÀGarantía propos limitada du thermostat de 1 año INDIRECTAMENTE, DEL INCUMPLIMIENTO DE LAS GARANTÍAS, EXPRESAS O IMPLICÍTAS, O DE OTRAS FALLAS DE ESTE PRODUCTO. Algunos estados no permiten la exclusión o limitación del daño incidental o indirecto, entonces, esta limitación puede no resultar aplicable a su caso. LA PRESENTE GARANTÍA ES LA ÚNICA GARANTÍA EXPRESA QUE HONEYWELL PROPORCIONA RESPECTO DE ESTE PRODUCTO. LA DURACIÓN DE LAS GARANTÍAS IMPLÍCITAS, INCLUÍDAS LAS GARANTÍAS DE COMERCIABILIDAD Y APTITUD PARA UN OBJETIVO PARTICULAR, ESTÁ LIMITADA A LA DURACIÓN DE UN AÑO DE LA PRESENTE GARANTÍA. Algunos estados no permiten las limitaciones sobre la duración del período de una garantía implícita, entonces la limitación anterior puede no resultar aplicable a su caso. Esta garantía le brinda derechos legales específicos, y usted podrá tener otros derechos que varían según el estado. Si tiene preguntas sobre la presente garantía, sírvase escribir a Honeywell Customer Relations, 1985 Douglas Dr, Golden Valley, MN 55422 o llamar al 1-800-468-1502. 69-2222ES—07 24 Serie RTH7400/RTH7500 25 69-2222ES—07 Soluciones para automatización y control Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 http://yourhome.honeywell.com ® Marca registrada de los EE. UU. © 2013, Honeywell International Inc. 69-2222ES—07 M.S. Rev. 11-2013 Impreso en EE.UU

No comments:

Post a Comment

Popular Posts