Honeywell Thermostat TH5220D1003 Manual - Honeywell Thermostat Manual Download

Latest

Sunday, April 5, 2020

Honeywell Thermostat TH5220D1003 Manual

6-436.9 5H76292A August, 2009 Honeywell TH5220D1003 thermostat wiring for gas unit heaters HD/HDB, HDS/HDC, PTS/BTS, PTC, PDP/BDP, and duct furnaces “D”, “H”, “I”, & “O” series WARNING 1. Disconnect power supply before making wiring connections to prevent electrical shock and equipment damage. 2. All units must be wired strictly in accordance with wiring diagram furnished with the unit. Any wiring different from the wiring diagram could result in a hazard to persons and property. 3. All wiring must be done with a wiring material having a temperature rating of at least 105°C. important Wiring Diagram Selection • For gas fired unit heaters and duct furnaces (non-factory 1. The use of this manual is specifically intended for a supplied blower) with model numbers shown above, refer to qualified installation and service agency. All installation and service of these kits must be performed by a qualified Figure 1.1 and Table 1.1 for correct unit to thermostat wiring. installation and service agency. • For all other system units (factory supplied blower), refer to 2. These instructions must also be used in conjunction with the job specific unit wiring diagram provided with the unit. the Installation and Service Manual that originally shipped with the appliance, in addition to any other accompanying • For deviations to these wiring diagrams or the job specific component supplier literature. wiring diagrams, consult the factory. Figure 1.1 - Terminals on Thermostat Installation and Wiring Installation of wiring must conform with local building codes, or in the absence of local codes of the National Electric Code ANSI/NFPA 70 - Latest Edition. Unit must be electrically grounded in conformance to this code. In Canada, wiring must comply with CSA C22.1, Part 1, Electrical Code. Table 1.1 - Thermostat to Unit Wiring  Wiring Terminals on Thermostat   Location of Unit Model W2 G W C R  Terminals (2-stage ONLY) HD/HDB, HDS/HDC, Ignition control in unit W2 G W1 C R  PTS/BTS control compartment Wiring Terminals on Unit Terminal board on PTC n/a G  T2 F T1 external junction box Gas valve high stage Terminal board on PDP/BDP F  T2 G T1 (HI, 3, or A) external junction box Fan relay by others or to Terminal board on Gas valve high stage DFG, IFG, DFP, IFP factory relay wire removed T G H external junction box (HI, 3, or A) from T or H (Digit 13=4 Only) Terminal strip in control  DFG, IFG, DFP, IFP, DFS, Factory time delay relay 3 4 2 1 compartment (Digit  IFS, HFG, OFG, HFP, OFP wire removed from 4 13=0, 1, 2, or 3) ➀ Not all terminal connections are used. Table only shows terminals that are used for required heating operation. ➁ The factory installed R to Rc terminal wire jumper is to remain in place. ➂ Verify that the buss bar on the G terminal is removed. ➃ Verify that the buss bar between the T2 and F terminal is removed. (See page 2 for Thermostat Function Programming Instructions) Downloaded from www.Manualslib.com manuals search engine Thermostat Function Program Selection Figure 2.1 - Buttons to Press to Enter Function • To enter thermostat setup mode, press and hold the s and Programming Mode FAN buttons until the display changes to setup mode. Use Press and hold to enter the s and t buttons to change settings, the NEXT button function programming mode to advance to the next setting, and the DONE button to save the settings and exit from the setup mode. • For gas fired unit heaters and duct furnaces (non-factory supplied blower) with model numbers shown on the opposite side, refer to Table 2.1 typical thermostat function settings. • For all other system units (factory supplied blower), refer to the job specific unit wiring diagram provided with the unit. • For deviations to these wiring diagrams or the job specific wiring diagrams, consult the factory. • For additional information, refer to the vendor literature supplied with the thermostat. Table 2.1 - Typical Thermostat Function Program Settings ➀ Function Typical Number Feature Setting Description 3 Single stage heat only with fan 1 System type 6 2 heat/2 cool conventional (cooling by others) 7 2 heat/1 cool conventional (cooling by others) 3 Fan control 0 Gas or oil furnace — equipment controls fan in heating 5 For gas or oil furnaces of less than 90% efficiency 5 Heat cycle rate (CPH) 3 For furnaces of over 90% efficiency 5 For gas or oil furnaces of less than 90% efficiency 6 Second stage heat cycle rate (CPH) 3 For furnaces of over 90% efficiency 9-12 Cooling functions   0 Fahrenheit 14 Temperature display 1 Celcius 15-26 Cooling and emergency heat functions   90 Default value, can be set 40-90 in increments of 1°F 27 Heat temperature range stops 80 For PTC models, this setting must be changed to 80 28 Cool temperature range stops 50  ➀ See Honeywell instructions that shipped with stat for more information and additional setting options. Commercial Products Group • Modine Manufacturing Company • 1500 DeKoven Avenue • Racine, Wisconsin 53403-2552 "D" & "H" Model Series and Gas Fired Unit Heaters - Phone: 1.800.828.4328 (HEAT) • Fax: 1.800.204.6011 "I" & "O" Model Series - Phone: 1.866.823.1631 (Toll Free) • Fax: 1.800.204.6011 © Modine Manufacturing Company 2009 Litho in USA 6-436.9 Downloaded from www.Manualslib.com manuals search engine

No comments:

Post a Comment

Popular Posts